inerex fire suppression system main image ul

INEREX: A COMPLETE GAS FIRE SUPPRESSION SYSTEM

A COMPLETE FIRE PROTECTION SYSTEM

All the components you need to configure a complete UL, FM & VdS Inert Gas total flooding fire suppression system.

UL, FM & VDS APPROVED

Product performance and production site tested and certified by UL, FM and VDS.

SAVES TIME AND EFFORT

Efficient design for easy installation and maintenance of the inert gas system..

AVAILABLE SOLUTIONS

Inert gas cylinder sizes 80L & 140L.
Both 200 bar and 300 bar.
All inert gas types : IG-01, IG-100, IG-55, IG-541.
Most reliable pressure regulator, from 300 bar down to 60 bar, generating significant savings.

FULL WARRANTY
PROTECTION

EASIER & FASTER INSTALLATION

SIMPLICITY OF A SINGLE SUPPLIER

INNOVATIVE FIRE PROTECTION SYSTEM

Inerex® by Rotarex Firetec is a complete UL, FM & VdS Approved Inert Gas Fire Suppression System that helps you save time and improves productivity

INEREX® has done the compatibility, performance testing and certification work for you! The system is ready to configure and install and the patented constant flow pressure regulator technology helps to improve safety and to ensure significant savings.

 

  • Key advantages: This inert gas fire suppression system is safe, effective and UL, FM Certified & VdS Approved
  • Fire protection system available for single and multi-zone protection
  • Protecting valuable assets, critical processes and life integrity in critical infrastructure
inerex inert gas fire suppression system graph

CONSTANT FLOW PRESSURE REGULATOR TECHNOLOGY

INEREX® fire protection systems use constant-flow pressure regulators that control the flow and the discharge pressure from 300 bar to a stable 40-60 bar which delivers the design quantity within 60 seconds, but with significant performance benefits:

BETTER SAFETY:
  • Prevents discharge freezing
  • Prevents discharge pressure peak
SAVES TIME & IMPROVES PRODUCTIVITY:
  • Enables low pressure (schedule 40) manifolds & pipework to be used – that are easy to install
  • Generates significant savings
  • Reduces the difficulty and cost of locating/fitting pressure vents in the protected space
EASY MAINTENENCE:
  • After a system discharge, simply remove the regulator, recharge and reconnect. No reconditioning necessary
  • Functional tests are possible even whilst the system is armed
 

COMPATILITY WITH INERT GAS EXTINGUISHING AGENTS

ADDITIONAL INFORMATION FOR GAS

All Rotarex fixed system components are compatible for use with all used inert gas extinguishing agents at 200 or 300 bar cylinder pressure.

Inert gases are naturally present in the air and have no impact on the environment. Inert gases are really efficient when extinguishing fire as they allow to reduce the oxygen of the area below the oxygen level required for combustion (15 %).

inert gases table type of agent
inerex fire suppression system certifications ul

INERT GAS SYSTEM CERTIFICATION

Firetec technology is approved and certified compliant with recognized international norms. The UL and FM logos indicate the associated components are part of a UL, FM listed system when configured in accordance with regulations such as NFPA 2001, UL 2127 and FM 5600.

In addition, all Rotarex manufacturing sites comply with ISO 9001 quality standards

APPLICATIONS

DATA CENTERS
OFFSHORE PLATFORMS
INDUSTRIAL PRODUCTION
BANKS & OFFICES
MUSEUMS
LABORATORIES
WINDTURBINES

SEND A INQUIRY

Address

Träslöv 7A, 432 91 Varberg, Sweden

Email

Tommy.paakkonen@firespect.se 4Service@firespect.se

Phone

+46 73 518 84 35